1. Why is the air-con operating but there isn't any cold air (air-con not cold) ?

The air conditioning system basically comprises of 2 sections. The indoor fancoil and the outdoor condenser. The indoor fancoil simply act as a blower to dissipate the cooling generated by the outdoor condenser. If there is no cool air blowing out from the indoor fancoil, the outdoor condenser might not be working. A qualified technician is needed to troubleshoot on the outdoor condenser.

 

2. Why is the air-con leaking water ?

A normal air conditioner will have water condensate in the indoor fancoil and discharge through a draining pipe to the nearest drain. Air Conditioner will start to leak water when the drainage piping is clogged / choked.

 

3. Why is the room not cold enough even after the air-con been running for few hours ?

There are a number of causes to this air conditioner not cold situation

Reason 1: The indoor fancoil is dirty resulting in weak dissipation of cool air.
Reason 2: The outdoor condenser is dirty resulting in incapable of producing cooling refrigerant. 
Reason 3: There may not be enough refrigerant in the air conditioning system. 
Reason 4: There might be some problem with the air conditioning system resulting in non-continuous operation of the system. 
Reason 5: The desired operating temperature is set too high. 
Reason 6: The air conditioner installed is under-sized.

 

4. Why is the air-con not working ?

One common reason is that the electrical power is not supply to the air conditioner. Perform an initial check on your electrical panel making sure that the electrical supply to the air conditioner has not trip. Upon confirmation of the availability of electrical supply, a qualified technician should be engaged to have the air conditioner repair.

 

5. What is the advantage of regular air-con service ?

Regular service of your air conditioning equipments will provide the following benefits:

Benefit 1: The air-conditioner will cool better.
Benefit 2: The electrical consumption of the air conditioning equipments will be lower. 
Benefit 3: Air-con leaking will be minimize. 
Benefit 4: There will be less need for air-con repair. 
Benefit 5: The air-con equipment lifespan will be prolong.

 

6. How often should I have the air-con service ?

In general, it is recommended that residential air conditioner is to be service and check every 3 months and every month for commercial air conditioner. The duration varies with different usage pattern and other environmental factors. Please seek the assessment of a qualified technician.

 

7. Can I do my own air-con maintenance ?

The basic maintenance that is recommended is the cleaning of the air filter and outer panel of the air conditioner every 2 weeks. This will helps to improve the air conditioning of the room.

 

8. Why is the air-con noisy ?

Noise is normally generated from

a. Vibration noise resulted from dirty indoor fancoil/ outdoor condenser. 
b. Noisy draft resulted from dirty indoor fancoil. 
c. Loose mounting of component in the air conditioning system. 
d. Faulty parts in the air conditioning system.

 

9. Why is the air-con smelly ?

The smell comes from bacteria formed by microbes in the warm dark humid environment in the indoor fancoil unit. Sometimes when the smell is very bad you may need a more intensive chemical treatment to rectify this problem.

 

10. Why does the air-con needs chemical cleaning / chemical washing ?

Chemical overhaul/cleaning is a very thorough way of cleaning the air conditioner. When an air conditioner is badly clogged/ choked and a general service can't improve the condition, an overhaul is necessary. In an overhaul, the air conditioner is dismantle part by part and chemically wash.

 

11. Why must the fancoil unit be dismantle for chemical cleaning / chemical washing instead of inserting a water tray to wash away the chemical ?

By dismantling the fan coil unit, the air conditioning individual components can be washed thoroughly. This will help better clean the unit and also not leaving behind chemical residue that may lead to the corrosion of the fan coil.

 

12. What should be done if there is a refrigerant leakage problem ?

If your air conditioning system has a refrigerant leak problem, simply adding of refrigerant (R22 / R410) is not a solution. A trained technician should perform test to trace and repair the leak. Upon completion of leakage repair, a correct amount of refrigerant should be top up.

 

13. What is the advantage of Air Purifying Filter and how often do we have to replace it ?

Most new model of air conditioner comes with air purifying filter. Air Purifying Filter can remove smoking odour, human smell, impurities and harmful particles in the air condition space. Its recommended that the purifying filter is replaced every three to six months. Or the color of purifying filter (originally white color) is changed to dark brown or black. Leaving dirty air purifying filter in the air conditioning system will affect its cooling performance.

 

14. Do we need to service the Condenser (outdoors) ? If, yes, how often ?

You need to service the condenser (outdoor air conditioning unit) at least once a year to make sure the air circulation of the unit is not blocked. It can affect the cooling efficiency, a shorter compressor life and higher electrical consumption. Sometimes, it is subjected to environmental condition, which requires a qualified technician to give recommendations.

 

15. Why does ice-forms on the copper pipes of the condenser (outdoor)?

There are 2 possibilities. Ice-forming on the discharged pipe is due to insufficient gas in the system. Ice-formation on the suction pipe could be caused by a dirty fancoil unit or, a dirty filter or, the indoor unit blower is not rotating.

 

16. Why is the air con switches OFF by itself and the air-con indicator light is blinking / flashing ?

The blinking / flashing of indicator light indicate that there is a fault with the air conditioning system. Hence the air conditioner switches off by itself. A qualified technician is needed to diagnose and repair the fault. As this is a protective function to prevent the air conditioner from further damage, it is not advisable to do a electrical power reset to get the air-con temporary working. Continue operation might further damage the air conditioning system.

 

17. Why is the air con switches ON and OFF by itself ?

There is a fault with the indoor electronic circuit board. The circuit board control the operation of the indoor fancoil and a damage cause it to lost its operational control. A repair or replacement of the circuit board is necessary.

 

18. Why is the air conditioner cannot be switch ON using the remote control ?

The fault might lies in the remote controller or the indoor printed circuit board. Try the remote controller on other fancoil and if it work, your remote controller is fine. If the fault lies in the printed circuit board, you need to engage a qualified technician to do repair on the printed circuit board.

 

19. What is pressure testing of air conditioning system and why it is needed ?

When the refrigerant gas in an air conditioning system depletes away and the air conditioner needs to regularly top up refrigerant gas, we can suspect that there is a refrigerant leakage in the air conditioning system. Pressure testing work will help to identify which is the leakage area. Normally high pressure is induced into the condenser, fancoil and refrigerant piping to identify where is the leakage. Further repair work will be quoted upon identifying the leakage area.
Note: Pressure testing work is a testing process (not repair work) to identify the leakage area. This work will not be able to rectify the fault but it’s a necessary process to define the scope of repair deriving from the result of the testing work. The leakage area defined herein is an indicative section of the refrigerant system. Our pressure test are unable to pinpoint leakage location.

 

20. Can faulty air-con printed circuit board (PCB) be repair instead of replacing new circuit board ?

Faulty circuit board can be repair in many cases. Many companies lack the knowleldge as well as do not want to waste time and effort on checking, repairing and testing of the circuit board. Its less time consuming to replace a new circuit board however the cost of replacing new circuit board is much more expensive.

 

Installation Questions :

1. What should I consider when choosing an air conditioner for my premise ?

The following are some factors you should consider when choosing an air conditioning system.

1.Determine the size of the area for which the air conditioner is require to cool. 
2.Determine the cooling capacity required (refer to question 2 under this section). 
3.Determine the brands and types of air condition you prefer. 
4.Workout and compare your budget.

 

2. How to determine the cooling capacity (air-con BTU) require for a room ?

An estimate calculation of cooling capacity for a room:

Area of Room [ Length (ft) x Width (ft) ] x 65 = "Cooling Capacity" BTU/Hr

Example: Room size is 12ft by 12ft. Cooling Capacity = (12ft x 12ft) x 65 = 9,360 BTU/hr

 


3. What is an inverter air conditioner ?

An inverter air conditioning system has a variable speed compressor as compare to non-inverter air conditioning system. The rotation speed frequency is regulated intelligently to meet specific cooling load requirement. Power consumption is thus more efficient.

 

4. What is the warranty on a new air conditioning system ?

The general warranty given by most manufactures are one (1) year on general parts and five (5) years on compressor.

 

Hotline: 6846 7837 [5 Lines] Fax: 6262 5512  Mon-Sat 9am-7pm  Sun & PH Closed

Office Address: 280 Woodlands Industrial Park E5 #10-43 Harvest @ Woodlands Singapore 757322

Walk-ins: By appointment only.  Please call for appointment.

Reg No: 53250187W   Gst Reg No: M90371021A

Email: sales@stlairconditioning.com.sg

© Copyright 2016  STL Air Conditioning